8 TXBiPFEMAutoDetect  = 00 # Length: 1; Unit: Options (0: Manual Mode, 1: Automatic mode); Format: Unsigned; Source: Customer; Comment: This parameter is used by the FW to decide if the front-end is determined automatically or manually
12 ClockValidOnWakeup = 00 # Length: 1; Unit: Options (0: Reference clock not valid, 1: Reference clock is valid and stable); Format: Unsigned; Source: Customer; Comment: This parameter indicates whether the FREF clock is valid on wakeup
15 TCXO_ClockValidOnWakeup = 00 # Length: 1; Unit: Options (0: Reference clock not valid, 1: Reference clock is valid and stable); Format: Unsigned; Source: Customer; Comment: This parameter indicates whether the TCXO clock is valid on wakeup
36 RxTraceInsertionLoss_2_4G = 00 # Length: 1; Unit: 1/8dB; Format: Unsigned; Source: Customer; Comment: This parameter indicates the printed circuit board (PCB) trace insertion loss
37 TxTraceLoss_2_4G = 00 00 00 00 00 00 00 00 00 00 00 00 00 00 # Length: 14; Unit: 1/8dB; Format: Unsigned; Source: Customer; Comment: This parameter is used to align the output power to a different location on the board
41 RxTraceInsertionLoss_5G = 00 00 00 00 00 00 00 # Length: 7; Unit: 1/8dB; Format: Unsigned; Source: Customer; Comment: This parameter indicates the printed circuit board (PCB) trace insertion loss
42 TxTraceLoss_5G = 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 # Length: 35; Unit: 1/8dB; Format: Unsigned; Source: Customer; Comment: This parameter is used to align the output power to a different location on the board
53 FEM1_TxBiPReferencePDvoltage_2_4G = 01D9 # Length: 1; Unit: 1mV; Format: Unsigned; Source: TI; Comment: This parameter define the reference point of the FEM power detector
63 FEM1_TxPDVsRateOffsets_2_4G = 01 02 02 02 02 00 02 # Length: 7; Unit: 1/8dB; Format: Signed; Source: TI; Comment: This parameter is a power detector offset value used to correct the power detector curve for each rate group
64 FEM1_TxPDVsChannelOffsets_2_4G = 00 00 00 00 00 00 00 00 00 00 00 00 00 00 # Length: 14; Unit: 1/8dB; Format: Signed; Source: TI/Customer; Comment: This parameter is a power detector offset value used to correct the power detector curve for each channel
65 FEM1_TxPDVsTemperature_2_4G = 00 00 # Length: 2; Unit: 1/8dB; Format: Signed; Source: TI; Comment: This parameter is a power detector offset value used to correct the power detector curve for each temperture
66 FEM1_TxIbiasTable_2_4G = 17 17 17 1a 16 17 1a 17 # Length: 8; Unit: Codeword ; Format: Unsigned; Source: TI; Comment: This parameter sets the bias current provided by the SoC to the PA in the FEM. Options (MCS7, 54/48, 36/24, 18/12, 9/6, 11b, MCS0, 11bCh14)
67 FEM1_RxFemInsertionLoss_2_4G = 10 # Length: 1; Unit: 1/8dB; Format: Unsigned; Source: TI; Comment: This parameter specifies the received insertion loss of the WL128x
71 FEM1_TxBiPReferencePDvoltage_5G = 019A 01AE 01C2 01CC 01DB 01DB 01D1 # Length: 7; Unit: 1mV; Format: Unsigned; Source: TI; Comment: This parameter define the reference point of the FEM power detector
80 FEM1_TxPDVsRateOffsets_5G = 01 02 02 02 02 00 02 # Length: 7; Unit: 1/8dB; Format: Signed; Source: TI; Comment: This parameter is a power detector offset value used to correct the power detector curve for each rate group
81 FEM1_TxPDVsChannelOffsets_5G = 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 # Length: 35; Unit: 1/8dB; Format: Signed; Source: TI/Customer; Comment: This parameter is a power detector offset value used to correct the power detector curve for each channel
82 FEM1_TxPDVsTemperature_5G = 00 00 00 00 00 00 00 00 00 00 00 00 00 00 # Length: 14; Unit: 1/8dB; Format: Signed; Source: TI; Comment: This parameter is a power detector offset value used to correct the power detector curve for each temperture
83 FEM1_TxIbiasTable_5G = 10 10 10 10 10 10 10 # Length: 7; Unit: Codeword; Format: Unsigned; Source: TI; Comment: This parameter sets the bias current provided by the SoC to the PA in the FEM
84 FEM1_RxFemInsertionLoss_5G = 10 10 10 10 10 10 10 # Length: 7; Unit: 1/8dB; Format: Unsigned; Source: TI; Comment: This parameter specifies the received insertion loss of the WL128x