Home | History | Annotate | Download | only in doc

Lines Matching refs:amplitude

51 decoding the curve amplitude and \varname{[floor0_order]} LSP
58 1) [amplitude] = read an unsigned integer of [floor0_amplitude_bits] bits
59 2) if ( [amplitude] is greater than zero ) \{
78 \item An \varname{[amplitude]} value of zero must result in a return code that indicates this channel is unused in this frame (the output of the channel will be all-zeroes in synthesis). Several later stages of decode don't occur for an unused channel.
82 \varname{[amplitude]} value had read zero at the beginning of decode.
106 Given an \varname{[amplitude]} integer and \varname{[coefficients]}
113 If the value \varname{[amplitude]} is zero, the return value is a
148 (dB) amplitude scale, mapping it to linear amplitude in the last step:
175 \exp \left( .11512925 \left(\frac{\mathtt{amplitude} \cdot \mathtt{floor0\_amplitute\_offset}}{(2^{\mathtt{floor0\_amplitude\_bits}}-1)\sqrt{p+q}}