Lines Matching full:applied
56 FEM1_TxPerRatePowerLimits_2_4G_Normal = 1D 1F 22 26 27 29 25 # Length: 7; Unit: 1/2dB; Format: Signed; Source: Customer; Comment: The limits are applied to the power control process according to the VBAT and temperature range in which the FEM is operating
57 FEM1_TxPerRatePowerLimits_2_4G_Degraded = 1D 1F 22 26 27 27 24 # Length: 7; Unit: 1/2dB; Format: Signed; Source: Customer; Comment: The limits are applied to the power control process according to the VBAT and temperature range in which the FEM is operating
58 FEM1_TxPerRatePowerLimits_2_4G_Extreme = 16 1D 1E 20 24 25 22 # Length: 7; Unit: 1/2dB; Format: Signed; Source: Customer; Comment: The limits are applied to the power control process according to the VBAT and temperature range in which the FEM is operating
59 FEM1_DegradedLowToNormalThr_2_4G = 1E # Length: 1; Unit: 1/10 volts; Format: Unsigned; Source: TI; Comment: The limits are applied to the power control process according to the VBAT and temperature range in which the FEM is operating
60 FEM1_NormalToDegradedHighThr_2_4G = 2D # Length: 1; Unit: 1/10 volts; Format: Unsigned; Source: TI; Comment: The limits are applied to the power control process according to the VBAT and temperature range in which the FEM is operating
74 FEM1_TxPerRatePowerLimits_5G_Normal = 1C 1E 21 23 25 50 25 # Length: 7; Unit: 1/2dB; Format: Signed; Source: Customer; Comment: The limits are applied to the power control process according to the VBAT and temperature range in which the FEM is operating
75 FEM1_TxPerRatePowerLimits_5G_Degraded = 18 1E 21 23 25 50 24 # Length: 7; Unit: 1/2dB; Format: Signed; Source: Customer; Comment: The limits are applied to the power control process according to the VBAT and temperature range in which the FEM is operating
76 FEM1_TxPerRatePowerLimits_5G_Extreme = 16 1C 1E 20 20 50 1E # Length: 7; Unit: 1/2dB; Format: Signed; Source: Customer; Comment: The limits are applied to the power control process according to the VBAT and temperature range in which the FEM is operating
77 FEM1_DegradedLowToNormalThr_5G = 1E # Length: 1; Unit: 1/10 volts; Format: Unsigned; Source: TI; Comment: The limits are applied to the power control process according to the VBAT and temperature range in which the FEM is operating
78 FEM1_NormalToDegradedHighThr_5G = 2D # Length: 1; Unit: 1/10 volts; Format: Unsigned; Source: TI; Comment: The limits are applied to the power control process according to the VBAT and temperature range in which the FEM is operating