HomeSort by relevance Sort by last modified time
    Searched full:motor (Results 1 - 25 of 157) sorted by null

1 2 3 4 5 6 7

  /external/kernel-headers/original/uapi/linux/
phantom.h 47 #define PHN_ZERO_FORCE 2048 /* zero torque on motor */
  /prebuilts/gcc/linux-x86/host/x86_64-linux-glibc2.11-4.6/sysroot/usr/include/linux/
phantom.h 47 #define PHN_ZERO_FORCE 2048 /* zero torque on motor */
  /prebuilts/gcc/linux-x86/host/x86_64-linux-glibc2.11-4.8/sysroot/usr/include/linux/
phantom.h 47 #define PHN_ZERO_FORCE 2048 /* zero torque on motor */
  /development/ndk/platforms/android-3/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/4/platforms/android-3/arch-arm/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/4/platforms/android-4/arch-arm/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/4/platforms/android-5/arch-arm/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/4/platforms/android-5/arch-x86/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/4/platforms/android-8/arch-arm/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/4/platforms/android-8/arch-x86/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/5/platforms/android-3/arch-arm/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/6/platforms/android-3/arch-arm/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/6/platforms/android-3/arch-x86/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/7/platforms/android-14/arch-arm/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/7/platforms/android-14/arch-x86/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/7/platforms/android-3/arch-arm/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/7/platforms/android-3/arch-x86/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/7/platforms/android-4/arch-arm/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/7/platforms/android-4/arch-x86/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/7/platforms/android-5/arch-arm/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/7/platforms/android-5/arch-x86/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/7/platforms/android-8/arch-arm/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/7/platforms/android-8/arch-x86/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/7/platforms/android-9/arch-arm/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }
  /prebuilts/ndk/7/platforms/android-9/arch-x86/usr/include/linux/
qic117.h 121 #define QIC117_ERRORS { { "No error", 0, }, { "Command Received while Drive Not Ready", 0, }, { "Cartridge Not Present or Removed", 1, }, { "Motor Speed Error (not within 1%)", 1, }, { "Motor Speed Fault (jammed, or gross speed error", 1, }, { "Cartridge Write Protected", 1, }, { "Undefined or Reserved Command Code", 1, }, { "Illegal Track Address Specified for Seek", 1, }, { "Illegal Command in Report Subcontext", 0, }, { "Illegal Entry into a Diagnostic Mode", 1, }, { "Broken Tape Detected (based on hole sensor)", 1, }, { "Warning--Read Gain Setting Error", 1, }, { "Command Received While Error Status Pending (obs)", 1, }, { "Command Received While New Cartridge Pending", 1, }, { "Command Illegal or Undefined in Primary Mode", 1, }, { "Command Illegal or Undefined in Format Mode", 1, }, { "Command Illegal or Undefined in Verify Mode", 1, }, { "Logical Forward Not at Logical BOT or no Format Segments in Format Mode", 1, }, { "Logical EOT Before All Segments generated", 1, }, { "Command Illegal When Cartridge Not Referenced", 1, }, { "Self-Diagnostic Failed (cannot be cleared)", 1, }, { "Warning EEPROM Not Initialized, Defaults Set", 1, }, { "EEPROM Corrupted or Hardware Failure", 1, }, { "Motion Time-out Error", 1, }, { "Data Segment Too Long -- Logical Forward or Pause", 1, }, { "Transmit Overrun (obs)", 1, }, { "Power On Reset Occurred", 0, }, { "Software Reset Occurred", 0, }, { "Diagnostic Mode 1 Error", 1, }, { "Diagnostic Mode 2 Error", 1, }, { "Command Received During Non-Interruptible Process", 1, }, { "Rate or Format Selection Error", 1, }, { "Illegal Command While in High Speed Mode", 1, }, { "Illegal Seek Segment Value", 1, }, { "Invalid Media", 1, }, { "Head Positioning Failure", 1, }, { "Write Reference Burst Failure", 1, }, { "Prom Code Missing", 1, }, { "Invalid Format", 1, }, { "EOT/BOT System Failure", 1, }, { "Prom A Checksum Error", 1, }, { "Drive Wakeup Reset Occurred", 1, }, { "Prom B Checksum Error", 1, }, { "Illegal Entry into Format Mode", 1, }, }

Completed in 1875 milliseconds

1 2 3 4 5 6 7