/frameworks/base/packages/SystemUI/src/com/android/systemui/statusbar/policy/ |
BatteryController.java | 48 void onBatteryLevelChanged(int level, boolean pluggedIn, boolean charging);
|
/frameworks/base/core/java/android/os/ |
BatteryManager.java | 29 * provides a method for querying battery and charging properties. 106 * Int value set to the maximum charging current supported by the charger in micro amperes. 113 * Int value set to the maximum charging voltage supported by the charger in micro volts. 155 * Sent when the device's battery has started charging (or has reached full charge 163 public static final String ACTION_CHARGING = "android.os.action.CHARGING"; 222 * Return true if the battery is currently considered to be charging. This means that
|
/external/autotest/server/site_tests/firmware_TypeCProbeUSB3/ |
firmware_TypeCProbeUSB3.py | 40 # Enumerate USB devices when charging. 43 logging.info('number of devices while charging: %d',
|
/external/autotest/server/site_tests/power_ChargeStatus/ |
power_ChargeStatus.py | 50 """Tests when on AC- the Main line is "ON" and "Charging/Charged". 57 if not (ac_state == "yes" and (bat_state == "Charging"
|
/external/chromium-trace/catapult/devil/devil/android/sdk/ |
fastboot.py | 95 """Sets off mode charging 98 value: boolean value to set off-mode-charging on or off.
|
/frameworks/base/docs/html/training/monitoring-device-state/ |
index.jd | 53 <dt><b><a href="battery-monitoring.html">Monitoring the Battery Level and Charging State</a></b></dt> 55 level and changes in charging state.</dd>
|
/frameworks/base/docs/html-intl/intl/ja/training/monitoring-device-state/ |
battery-monitoring.jd | 48 <pre>// Are we charging / charged? 53 // How are we charging?
|
/frameworks/base/docs/html-intl/intl/zh-cn/training/monitoring-device-state/ |
battery-monitoring.jd | 48 <pre>// Are we charging / charged? 53 // How are we charging?
|
/prebuilts/gcc/linux-x86/host/x86_64-w64-mingw32-4.8/x86_64-w64-mingw32/include/ |
batclass.h | 68 BOOLEAN Charging; 110 BOOLEAN Charging;
|
/system/core/healthd/include/healthd/ |
healthd.h | 31 // overheat due to charging). The default value is 60 (1 minute). Value 43 // batteryStatusPath: charging status (POWER_SUPPLY_PROP_STATUS)
|
/external/autotest/server/site_tests/power_BatteryStateOnResume/ |
control | 15 3. Battery charge state reports "Charging" on Resume when AC is plugged to
|
/external/nist-sip/java/gov/nist/javax/sip/header/ |
HeaderFactoryExt.java | 124 * P-Charging-Function-Addresses header 126 * @return newly created P-Charging-Function-Addresses header 131 * P-Charging-Vector header 135 * @return newly created P-Charging-Vector header
|
/frameworks/base/docs/html-intl/intl/ru/training/monitoring-device-state/ |
docking-monitoring.jd | 6 previous.title= Monitoring the Battery Level and Charging State
|
/frameworks/base/tests/JobSchedulerTestApp/res/values/ |
strings.xml | 27 <string name="charging_caption">Charging:</string>
|
/prebuilts/misc/windows/sdl2/test/ |
testpower.c | 36 statestr = "Charging";
|
/cts/apps/CtsVerifier/src/com/android/cts/verifier/jobscheduler/ |
ChargingConstraintTestActivity.java | 23 * - Ask the tester to ensure the phone is plugged in, and verify that jobs with charging 25 * - Ask the tester to unplug the phone, and verify that jobs with charging constraints will 37 // to get into charging mode.
|
/external/autotest/server/site_tests/platform_PowerStatusStress/ |
platform_PowerStatusStress.py | 9 _CHARGING = 'CHARGING' 159 # Charging state - it could be any of the three below 160 expected = ('yes', 'AC', '(Charging|Fully charged|Discharging)')
|
/external/nist-sip/java/gov/nist/javax/sip/header/ims/ |
PChargingVector.java | 40 * P-Charging-Vector header SIP Private Header: RFC 3455. 120 + "P-Charging-Vector, setICID(), the icid parameter is null."); 153 + "P-Charging-Vector, setICIDGeneratedAt(), the host parameter is null.");
|
/frameworks/base/packages/SettingsLib/res/values/ |
strings.xml | 392 <string name="keep_screen_on_summary">Screen will never sleep while charging</string> [all...] |
/frameworks/base/packages/SystemUI/src/com/android/systemui/statusbar/car/ |
CarBatteryController.java | 101 // There is no way to know if the phone is plugged in or charging via bluetooth, so pass 103 cb.onBatteryLevelChanged(mLevel, false /* pluggedIn */, false /* charging */); 256 .onBatteryLevelChanged(mLevel, false /* pluggedIn */, false /* charging */);
|
/frameworks/base/packages/SystemUI/src/com/android/systemui/statusbar/phone/ |
KeyguardStatusBarView.java | 230 public void onBatteryLevelChanged(int level, boolean pluggedIn, boolean charging) { 233 boolean changed = mBatteryCharging != charging; 234 mBatteryCharging = charging;
|
/cts/tests/JobScheduler/src/android/jobscheduler/cts/ |
ConstraintTest.java | 32 /** Force the scheduler to consider the device to be on stable charging. */
|
/device/google/dragon/health/ |
healthd-dragon.cpp | 70 * if not charging and State-Of-Charge (soc) is below
|
/device/huawei/angler/ |
init.angler.usb.rc | 32 setprop persist.sys.usb.config charging 141 # USB charging configuration 142 on property:sys.usb.config=charging 147 write /sys/class/android_usb/android0/functions charging
|
/docs/source.android.com/src/devices/accessories/ |
protocol.jd | 29 that support accessory mode, and must provide 500mA at 5V for charging power.
|