Home | History | Annotate | Download | only in CodeGen
      1 //===-- RegisterPressure.h - Dynamic Register Pressure -*- C++ -*-------===//
      2 //
      3 //                     The LLVM Compiler Infrastructure
      4 //
      5 // This file is distributed under the University of Illinois Open Source
      6 // License. See LICENSE.TXT for details.
      7 //
      8 //===----------------------------------------------------------------------===//
      9 //
     10 // This file defines the RegisterPressure class which can be used to track
     11 // MachineInstr level register pressure.
     12 //
     13 //===----------------------------------------------------------------------===//
     14 
     15 #ifndef LLVM_CODEGEN_REGISTERPRESSURE_H
     16 #define LLVM_CODEGEN_REGISTERPRESSURE_H
     17 
     18 #include "llvm/ADT/SparseSet.h"
     19 #include "llvm/CodeGen/SlotIndexes.h"
     20 #include "llvm/Target/TargetRegisterInfo.h"
     21 
     22 namespace llvm {
     23 
     24 class LiveIntervals;
     25 class LiveRange;
     26 class RegisterClassInfo;
     27 class MachineInstr;
     28 
     29 /// Base class for register pressure results.
     30 struct RegisterPressure {
     31   /// Map of max reg pressure indexed by pressure set ID, not class ID.
     32   std::vector<unsigned> MaxSetPressure;
     33 
     34   /// List of live in virtual registers or physical register units.
     35   SmallVector<unsigned,8> LiveInRegs;
     36   SmallVector<unsigned,8> LiveOutRegs;
     37 
     38   void dump(const TargetRegisterInfo *TRI) const;
     39 };
     40 
     41 /// RegisterPressure computed within a region of instructions delimited by
     42 /// TopIdx and BottomIdx.  During pressure computation, the maximum pressure per
     43 /// register pressure set is increased. Once pressure within a region is fully
     44 /// computed, the live-in and live-out sets are recorded.
     45 ///
     46 /// This is preferable to RegionPressure when LiveIntervals are available,
     47 /// because delimiting regions by SlotIndex is more robust and convenient than
     48 /// holding block iterators. The block contents can change without invalidating
     49 /// the pressure result.
     50 struct IntervalPressure : RegisterPressure {
     51   /// Record the boundary of the region being tracked.
     52   SlotIndex TopIdx;
     53   SlotIndex BottomIdx;
     54 
     55   void reset();
     56 
     57   void openTop(SlotIndex NextTop);
     58 
     59   void openBottom(SlotIndex PrevBottom);
     60 };
     61 
     62 /// RegisterPressure computed within a region of instructions delimited by
     63 /// TopPos and BottomPos. This is a less precise version of IntervalPressure for
     64 /// use when LiveIntervals are unavailable.
     65 struct RegionPressure : RegisterPressure {
     66   /// Record the boundary of the region being tracked.
     67   MachineBasicBlock::const_iterator TopPos;
     68   MachineBasicBlock::const_iterator BottomPos;
     69 
     70   void reset();
     71 
     72   void openTop(MachineBasicBlock::const_iterator PrevTop);
     73 
     74   void openBottom(MachineBasicBlock::const_iterator PrevBottom);
     75 };
     76 
     77 /// Capture a change in pressure for a single pressure set. UnitInc may be
     78 /// expressed in terms of upward or downward pressure depending on the client
     79 /// and will be dynamically adjusted for current liveness.
     80 ///
     81 /// Pressure increments are tiny, typically 1-2 units, and this is only for
     82 /// heuristics, so we don't check UnitInc overflow. Instead, we may have a
     83 /// higher level assert that pressure is consistent within a region. We also
     84 /// effectively ignore dead defs which don't affect heuristics much.
     85 class PressureChange {
     86   uint16_t PSetID; // ID+1. 0=Invalid.
     87   int16_t  UnitInc;
     88 public:
     89   PressureChange(): PSetID(0), UnitInc(0) {}
     90   PressureChange(unsigned id): PSetID(id+1), UnitInc(0) {
     91     assert(id < UINT16_MAX && "PSetID overflow.");
     92   }
     93 
     94   bool isValid() const { return PSetID > 0; }
     95 
     96   unsigned getPSet() const {
     97     assert(isValid() && "invalid PressureChange");
     98     return PSetID - 1;
     99   }
    100   // If PSetID is invalid, return UINT16_MAX to give it lowest priority.
    101   unsigned getPSetOrMax() const { return (PSetID - 1) & UINT16_MAX; }
    102 
    103   int getUnitInc() const { return UnitInc; }
    104 
    105   void setUnitInc(int Inc) { UnitInc = Inc; }
    106 
    107   bool operator==(const PressureChange &RHS) const {
    108     return PSetID == RHS.PSetID && UnitInc == RHS.UnitInc;
    109   }
    110 };
    111 
    112 template <> struct isPodLike<PressureChange> {
    113    static const bool value = true;
    114 };
    115 
    116 /// List of PressureChanges in order of increasing, unique PSetID.
    117 ///
    118 /// Use a small fixed number, because we can fit more PressureChanges in an
    119 /// empty SmallVector than ever need to be tracked per register class. If more
    120 /// PSets are affected, then we only track the most constrained.
    121 class PressureDiff {
    122   // The initial design was for MaxPSets=4, but that requires PSet partitions,
    123   // which are not yet implemented. (PSet partitions are equivalent PSets given
    124   // the register classes actually in use within the scheduling region.)
    125   enum { MaxPSets = 16 };
    126 
    127   PressureChange PressureChanges[MaxPSets];
    128 public:
    129   typedef PressureChange* iterator;
    130   typedef const PressureChange* const_iterator;
    131   iterator begin() { return &PressureChanges[0]; }
    132   iterator end() { return &PressureChanges[MaxPSets]; }
    133   const_iterator begin() const { return &PressureChanges[0]; }
    134   const_iterator end() const { return &PressureChanges[MaxPSets]; }
    135 
    136   void addPressureChange(unsigned RegUnit, bool IsDec,
    137                          const MachineRegisterInfo *MRI);
    138 };
    139 
    140 /// Array of PressureDiffs.
    141 class PressureDiffs {
    142   PressureDiff *PDiffArray;
    143   unsigned Size;
    144   unsigned Max;
    145 public:
    146   PressureDiffs(): PDiffArray(nullptr), Size(0), Max(0) {}
    147   ~PressureDiffs() { free(PDiffArray); }
    148 
    149   void clear() { Size = 0; }
    150 
    151   void init(unsigned N);
    152 
    153   PressureDiff &operator[](unsigned Idx) {
    154     assert(Idx < Size && "PressureDiff index out of bounds");
    155     return PDiffArray[Idx];
    156   }
    157   const PressureDiff &operator[](unsigned Idx) const {
    158     return const_cast<PressureDiffs*>(this)->operator[](Idx);
    159   }
    160 };
    161 
    162 /// Store the effects of a change in pressure on things that MI scheduler cares
    163 /// about.
    164 ///
    165 /// Excess records the value of the largest difference in register units beyond
    166 /// the target's pressure limits across the affected pressure sets, where
    167 /// largest is defined as the absolute value of the difference. Negative
    168 /// ExcessUnits indicates a reduction in pressure that had already exceeded the
    169 /// target's limits.
    170 ///
    171 /// CriticalMax records the largest increase in the tracker's max pressure that
    172 /// exceeds the critical limit for some pressure set determined by the client.
    173 ///
    174 /// CurrentMax records the largest increase in the tracker's max pressure that
    175 /// exceeds the current limit for some pressure set determined by the client.
    176 struct RegPressureDelta {
    177   PressureChange Excess;
    178   PressureChange CriticalMax;
    179   PressureChange CurrentMax;
    180 
    181   RegPressureDelta() {}
    182 
    183   bool operator==(const RegPressureDelta &RHS) const {
    184     return Excess == RHS.Excess && CriticalMax == RHS.CriticalMax
    185       && CurrentMax == RHS.CurrentMax;
    186   }
    187   bool operator!=(const RegPressureDelta &RHS) const {
    188     return !operator==(RHS);
    189   }
    190 };
    191 
    192 /// \brief A set of live virtual registers and physical register units.
    193 ///
    194 /// Virtual and physical register numbers require separate sparse sets, but most
    195 /// of the RegisterPressureTracker handles them uniformly.
    196 struct LiveRegSet {
    197   SparseSet<unsigned> PhysRegs;
    198   SparseSet<unsigned, VirtReg2IndexFunctor> VirtRegs;
    199 
    200   bool contains(unsigned Reg) const {
    201     if (TargetRegisterInfo::isVirtualRegister(Reg))
    202       return VirtRegs.count(Reg);
    203     return PhysRegs.count(Reg);
    204   }
    205 
    206   bool insert(unsigned Reg) {
    207     if (TargetRegisterInfo::isVirtualRegister(Reg))
    208       return VirtRegs.insert(Reg).second;
    209     return PhysRegs.insert(Reg).second;
    210   }
    211 
    212   bool erase(unsigned Reg) {
    213     if (TargetRegisterInfo::isVirtualRegister(Reg))
    214       return VirtRegs.erase(Reg);
    215     return PhysRegs.erase(Reg);
    216   }
    217 };
    218 
    219 /// Track the current register pressure at some position in the instruction
    220 /// stream, and remember the high water mark within the region traversed. This
    221 /// does not automatically consider live-through ranges. The client may
    222 /// independently adjust for global liveness.
    223 ///
    224 /// Each RegPressureTracker only works within a MachineBasicBlock. Pressure can
    225 /// be tracked across a larger region by storing a RegisterPressure result at
    226 /// each block boundary and explicitly adjusting pressure to account for block
    227 /// live-in and live-out register sets.
    228 ///
    229 /// RegPressureTracker holds a reference to a RegisterPressure result that it
    230 /// computes incrementally. During downward tracking, P.BottomIdx or P.BottomPos
    231 /// is invalid until it reaches the end of the block or closeRegion() is
    232 /// explicitly called. Similarly, P.TopIdx is invalid during upward
    233 /// tracking. Changing direction has the side effect of closing region, and
    234 /// traversing past TopIdx or BottomIdx reopens it.
    235 class RegPressureTracker {
    236   const MachineFunction     *MF;
    237   const TargetRegisterInfo  *TRI;
    238   const RegisterClassInfo   *RCI;
    239   const MachineRegisterInfo *MRI;
    240   const LiveIntervals       *LIS;
    241 
    242   /// We currently only allow pressure tracking within a block.
    243   const MachineBasicBlock *MBB;
    244 
    245   /// Track the max pressure within the region traversed so far.
    246   RegisterPressure &P;
    247 
    248   /// Run in two modes dependending on whether constructed with IntervalPressure
    249   /// or RegisterPressure. If requireIntervals is false, LIS are ignored.
    250   bool RequireIntervals;
    251 
    252   /// True if UntiedDefs will be populated.
    253   bool TrackUntiedDefs;
    254 
    255   /// Register pressure corresponds to liveness before this instruction
    256   /// iterator. It may point to the end of the block or a DebugValue rather than
    257   /// an instruction.
    258   MachineBasicBlock::const_iterator CurrPos;
    259 
    260   /// Pressure map indexed by pressure set ID, not class ID.
    261   std::vector<unsigned> CurrSetPressure;
    262 
    263   /// Set of live registers.
    264   LiveRegSet LiveRegs;
    265 
    266   /// Set of vreg defs that start a live range.
    267   SparseSet<unsigned, VirtReg2IndexFunctor> UntiedDefs;
    268   /// Live-through pressure.
    269   std::vector<unsigned> LiveThruPressure;
    270 
    271 public:
    272   RegPressureTracker(IntervalPressure &rp) :
    273     MF(nullptr), TRI(nullptr), RCI(nullptr), LIS(nullptr), MBB(nullptr), P(rp),
    274     RequireIntervals(true), TrackUntiedDefs(false) {}
    275 
    276   RegPressureTracker(RegionPressure &rp) :
    277     MF(nullptr), TRI(nullptr), RCI(nullptr), LIS(nullptr), MBB(nullptr), P(rp),
    278     RequireIntervals(false), TrackUntiedDefs(false) {}
    279 
    280   void reset();
    281 
    282   void init(const MachineFunction *mf, const RegisterClassInfo *rci,
    283             const LiveIntervals *lis, const MachineBasicBlock *mbb,
    284             MachineBasicBlock::const_iterator pos,
    285             bool ShouldTrackUntiedDefs = false);
    286 
    287   /// Force liveness of virtual registers or physical register
    288   /// units. Particularly useful to initialize the livein/out state of the
    289   /// tracker before the first call to advance/recede.
    290   void addLiveRegs(ArrayRef<unsigned> Regs);
    291 
    292   /// Get the MI position corresponding to this register pressure.
    293   MachineBasicBlock::const_iterator getPos() const { return CurrPos; }
    294 
    295   // Reset the MI position corresponding to the register pressure. This allows
    296   // schedulers to move instructions above the RegPressureTracker's
    297   // CurrPos. Since the pressure is computed before CurrPos, the iterator
    298   // position changes while pressure does not.
    299   void setPos(MachineBasicBlock::const_iterator Pos) { CurrPos = Pos; }
    300 
    301   /// \brief Get the SlotIndex for the first nondebug instruction including or
    302   /// after the current position.
    303   SlotIndex getCurrSlot() const;
    304 
    305   /// Recede across the previous instruction.
    306   bool recede(SmallVectorImpl<unsigned> *LiveUses = nullptr,
    307               PressureDiff *PDiff = nullptr);
    308 
    309   /// Advance across the current instruction.
    310   bool advance();
    311 
    312   /// Finalize the region boundaries and recored live ins and live outs.
    313   void closeRegion();
    314 
    315   /// Initialize the LiveThru pressure set based on the untied defs found in
    316   /// RPTracker.
    317   void initLiveThru(const RegPressureTracker &RPTracker);
    318 
    319   /// Copy an existing live thru pressure result.
    320   void initLiveThru(ArrayRef<unsigned> PressureSet) {
    321     LiveThruPressure.assign(PressureSet.begin(), PressureSet.end());
    322   }
    323 
    324   ArrayRef<unsigned> getLiveThru() const { return LiveThruPressure; }
    325 
    326   /// Get the resulting register pressure over the traversed region.
    327   /// This result is complete if either advance() or recede() has returned true,
    328   /// or if closeRegion() was explicitly invoked.
    329   RegisterPressure &getPressure() { return P; }
    330   const RegisterPressure &getPressure() const { return P; }
    331 
    332   /// Get the register set pressure at the current position, which may be less
    333   /// than the pressure across the traversed region.
    334   std::vector<unsigned> &getRegSetPressureAtPos() { return CurrSetPressure; }
    335 
    336   void discoverLiveOut(unsigned Reg);
    337   void discoverLiveIn(unsigned Reg);
    338 
    339   bool isTopClosed() const;
    340   bool isBottomClosed() const;
    341 
    342   void closeTop();
    343   void closeBottom();
    344 
    345   /// Consider the pressure increase caused by traversing this instruction
    346   /// bottom-up. Find the pressure set with the most change beyond its pressure
    347   /// limit based on the tracker's current pressure, and record the number of
    348   /// excess register units of that pressure set introduced by this instruction.
    349   void getMaxUpwardPressureDelta(const MachineInstr *MI,
    350                                  PressureDiff *PDiff,
    351                                  RegPressureDelta &Delta,
    352                                  ArrayRef<PressureChange> CriticalPSets,
    353                                  ArrayRef<unsigned> MaxPressureLimit);
    354 
    355   void getUpwardPressureDelta(const MachineInstr *MI,
    356                               /*const*/ PressureDiff &PDiff,
    357                               RegPressureDelta &Delta,
    358                               ArrayRef<PressureChange> CriticalPSets,
    359                               ArrayRef<unsigned> MaxPressureLimit) const;
    360 
    361   /// Consider the pressure increase caused by traversing this instruction
    362   /// top-down. Find the pressure set with the most change beyond its pressure
    363   /// limit based on the tracker's current pressure, and record the number of
    364   /// excess register units of that pressure set introduced by this instruction.
    365   void getMaxDownwardPressureDelta(const MachineInstr *MI,
    366                                    RegPressureDelta &Delta,
    367                                    ArrayRef<PressureChange> CriticalPSets,
    368                                    ArrayRef<unsigned> MaxPressureLimit);
    369 
    370   /// Find the pressure set with the most change beyond its pressure limit after
    371   /// traversing this instruction either upward or downward depending on the
    372   /// closed end of the current region.
    373   void getMaxPressureDelta(const MachineInstr *MI,
    374                            RegPressureDelta &Delta,
    375                            ArrayRef<PressureChange> CriticalPSets,
    376                            ArrayRef<unsigned> MaxPressureLimit) {
    377     if (isTopClosed())
    378       return getMaxDownwardPressureDelta(MI, Delta, CriticalPSets,
    379                                          MaxPressureLimit);
    380 
    381     assert(isBottomClosed() && "Uninitialized pressure tracker");
    382     return getMaxUpwardPressureDelta(MI, nullptr, Delta, CriticalPSets,
    383                                      MaxPressureLimit);
    384   }
    385 
    386   /// Get the pressure of each PSet after traversing this instruction bottom-up.
    387   void getUpwardPressure(const MachineInstr *MI,
    388                          std::vector<unsigned> &PressureResult,
    389                          std::vector<unsigned> &MaxPressureResult);
    390 
    391   /// Get the pressure of each PSet after traversing this instruction top-down.
    392   void getDownwardPressure(const MachineInstr *MI,
    393                            std::vector<unsigned> &PressureResult,
    394                            std::vector<unsigned> &MaxPressureResult);
    395 
    396   void getPressureAfterInst(const MachineInstr *MI,
    397                             std::vector<unsigned> &PressureResult,
    398                             std::vector<unsigned> &MaxPressureResult) {
    399     if (isTopClosed())
    400       return getUpwardPressure(MI, PressureResult, MaxPressureResult);
    401 
    402     assert(isBottomClosed() && "Uninitialized pressure tracker");
    403     return getDownwardPressure(MI, PressureResult, MaxPressureResult);
    404   }
    405 
    406   bool hasUntiedDef(unsigned VirtReg) const {
    407     return UntiedDefs.count(VirtReg);
    408   }
    409 
    410   void dump() const;
    411 
    412 protected:
    413   const LiveRange *getLiveRange(unsigned Reg) const;
    414 
    415   void increaseRegPressure(ArrayRef<unsigned> Regs);
    416   void decreaseRegPressure(ArrayRef<unsigned> Regs);
    417 
    418   void bumpUpwardPressure(const MachineInstr *MI);
    419   void bumpDownwardPressure(const MachineInstr *MI);
    420 };
    421 
    422 void dumpRegSetPressure(ArrayRef<unsigned> SetPressure,
    423                         const TargetRegisterInfo *TRI);
    424 } // end namespace llvm
    425 
    426 #endif
    427