Home | History | Annotate | Download | only in sensors
      1 page.title=Interaction
      2 @jd:body
      3 
      4 <!--
      5     Copyright 2014 The Android Open Source Project
      6 
      7     Licensed under the Apache License, Version 2.0 (the "License");
      8     you may not use this file except in compliance with the License.
      9     You may obtain a copy of the License at
     10 
     11         http://www.apache.org/licenses/LICENSE-2.0
     12 
     13     Unless required by applicable law or agreed to in writing, software
     14     distributed under the License is distributed on an "AS IS" BASIS,
     15     WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
     16     See the License for the specific language governing permissions and
     17     limitations under the License.
     18 -->
     19 
     20 <p>From the perspective of Android applications, every Android sensor is an
     21   independent entity, meaning there is no interaction between the different
     22   sensors.</p>
     23 <ul>
     24   <li> This is true even though several Android sensors might share the same
     25     underlying physical sensor </li>
     26   <li> For example: step counter, significant motion and accelerometer, all relying on
     27     the same physical accelerometer, must be able to work concurrently </li>
     28   <li> This is also true for wake-up and non-wake-up versions of the same sensor </li>
     29 </ul>
     30 <p>Android sensors must be able to work simultaneously and independently of one
     31   another. That is, any action on one Android sensor must not impact the behavior
     32   of the other sensors.</p>
     33 <p>Specifically, at the HAL level:</p>
     34 <ul>
     35   <li> activating a sensor </li>
     36   <li> deactivating a sensor </li>
     37   <li> changing the sampling frequency of a sensor </li>
     38   <li> changing the maximum reporting latency of a sensor </li>
     39 </ul>
     40 <p>cannot cause:</p>
     41 <ul>
     42   <li> another activated sensor to stop working </li>
     43   <li> another activated sensor to change sampling rate </li>
     44   <li> another activated sensor to decrease the quality of its measurements </li>
     45   <li> another non-activated sensor to start delivering events </li>
     46 </ul>
     47 <p>Nor can any of the actions above prevent actions (activation, deactivation,
     48   and parameter changes) on another sensor from succeeding. For instance,
     49   whether we can activate the step counter must be independent of whether the
     50   accelerometer is currently activated. </p>
     51 <p>As another important example, a wake-up sensor activated at 5Hz must generate events
     52   at around 5Hz, even if its non-wake-up variant is being activated at 100Hz.</p>
     53