Home | History | Annotate | Download | only in gas
      1 /*
      2  * Author: Jon Trulson <jtrulson (at) ics.com>
      3  * Copyright (c) 2015 Intel Corporation.
      4  *
      5  * Permission is hereby granted, free of charge, to any person obtaining
      6  * a copy of this software and associated documentation files (the
      7  * "Software"), to deal in the Software without restriction, including
      8  * without limitation the rights to use, copy, modify, merge, publish,
      9  * distribute, sublicense, and/or sell copies of the Software, and to
     10  * permit persons to whom the Software is furnished to do so, subject to
     11  * the following conditions:
     12  *
     13  * The above copyright notice and this permission notice shall be
     14  * included in all copies or substantial portions of the Software.
     15  *
     16  * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
     17  * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
     18  * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
     19  * NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE
     20  * LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION
     21  * OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION
     22  * WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
     23  */
     24 #pragma once
     25 
     26 #include <iostream>
     27 #include <string>
     28 #include "gas.h"
     29 
     30 namespace upm {
     31   /**
     32    * @library gas
     33    * @sensor mq8
     34    * @comname DFRobot MQ8 CO Gas Sensor
     35    * @type gaseous
     36    * @man dfrobot
     37    * @con analog
     38    *
     39    * @brief API for the DFRobot MQ8 Hydrogen (H2) Gas Sensor
     40    *
     41    * The MQ8 Gas Sensor module is useful for detecting Hydrogen gas
     42    * concentrations in the air.  It has a detection range of 100-10000
     43    * ppm.
     44    *
     45    * For optimum use, it requires calibration after a pre-heat time of
     46    * at least 24 hours.  See the datasheet for details.
     47    *
     48    * @image html mq2-5.jpeg
     49    * @snippet mq8.cxx Interesting
     50    */
     51     class MQ8 : public Gas {
     52         public:
     53             /**
     54              * MQ8 constructor
     55              *
     56              * @param gasPin Analog pin where the sensor is connected
     57              */
     58             MQ8 (int gasPin);
     59 
     60             /**
     61              * MQ8 destructor
     62              */
     63             ~MQ8 ();
     64 
     65             /**
     66              * Returns the name of the sensor
     67              */
     68             std::string name()
     69             {
     70                 return m_name;
     71             }
     72         private:
     73             std::string m_name;
     74     };
     75 }
     76